Civil Rights
Movements, leaders, victories and the continuing fight for equality.
Explore the people, places, events, achievements, struggles and stories that shaped our journey.
Movements, leaders, victories and the continuing fight for equality.
Innovation, patents, science, technology and world-changing contributions.
Pioneers, champions, Negro Leagues, records, activism and excellence.
Meet the people whose lives, choices and achievements shaped the journey.
Black towns, communities, institutions and places where history happened.
Moments that changed communities, movements, institutions and the nation.
Wilmington, North Carolina once had a thriving Black middle class and an elected interracial government. In 1898 white supremacists used violence to overthrow that government, kill Black residents and drive many others from the city.
MORE →Reflects the personal views, recollections, and perspective of the author, Mike Davis.
This is a personal recollection on the Move fire on May 13, 1985

An actinometer is an instrument that can measure the heating power of radiation. Actinometers are used in meteorology to measure solar radiation as pyranometers, pyrheliometers and net radiometers.
An actinometer is a chemical system or physical device which determines the number of photons in a beam integrally or per unit time. This name is commonly applied to devices used in the ultraviolet and visible wavelength ranges. For example, solutions of iron(III) oxalate can be used as a chemical actinometer, while bolometers, thermopiles, and photodiodes are physical devices giving a reading that can be correlated to the number of photons detected.
Swiss physicist Horace-Bénédict de Saussure invented an early version in the late 18th century. His design used a blackened thermometer enclosed in a glass sphere to measure solar radiation, which he referred to as a "heliothermometer." This instrument is considered one of the first tools to systematically measure solar intensity.
John Herschel further developed actinometers in the 19th century, including a design involving photochemical reactions to measure sunlight intensity, which was a significant step forward. Herschel's actinometer involved observing the rate of a chemical reaction under sunlight, which allowed for more precise quantification of solar energy. Herschel's version was influential and helped standardize measurements of solar energy. Herschel introduced the term actinometer, the first of many uses of the prefix actin for scientific instruments, effects, and processes.[1]
The actinograph is a related device for estimating the actinic power of lighting for photography.
Chemical actinometry involves measuring radiant flux via the yield from a chemical reaction. This process requires a chemical with a known quantum yield and easily analyzed reaction products.
Potassium ferrioxalate is commonly used, as it is simple to use and sensitive over a wide range of relevant wavelengths (254 nm to 500 nm). Other actinometers include malachite green Leucocyanidins, vanadium(V)–iron(III) oxalate and monochloroacetic acid, however all of these actinometers undergo dark reactions, that is, they react in the absence of light. This is undesirable since it will have to be corrected for. Organic actinometers like butyrophenone or piperylene are analysed by gas chromatography. Other actinometers are more specific in terms of the range of wavelengths at which quantum yields have been determined. Reinecke's salt K[Cr(NH3)2(NCS)4] reacts in the near-UV region although it is thermally unstable.[2][3][4] Uranyl oxalate has been used historically but is very toxic and cumbersome to analyze.
Recent investigations into nitrate photolysis[5][6] have used 2-nitrobenzaldehyde and benzoic acid as a radical scavenger for hydroxyl radicals produced in the photolysis of hydrogen peroxide and sodium nitrate. However, they originally used ferrioxalate actinometry to calibrate the quantum yields for the hydrogen peroxide photolysis. Radical scavengers proved a viable method of measuring production of hydroxyl radical.
Meso-diphenylhelianthrene can be used for chemical actinometry in the visible range (400–700 nm).[7] This chemical measures in the 475–610 nm range, but measurements in wider spectral ranges can be done with this chemical if the emission spectrum of the light source is known.
Relative actinometry (sometimes called also comparative actinometry) is a technique frequently used to determine formation quantum yields of triplet excited states using comparison with a well known reference compound.[8] The reference compound (for example [Ru(bpy)3]2+)[9] and the compound of interest should be prepared separately in the identical cuvettes so that each of them has the same absorbance at the excitation wavelength chosen for the experiment. This means that upon the excitation, the same number of molecules will be promoted to the excited state, given that the experimental conditions are identical. The reference compound forms a photoproduct of a well-characterized formation quantum yield and molar absorption coefficient. This allows to calculate formation quantum yield or molar absorption coefficient for the photoproduct of the compound of interest. For example, when using transient absorption spectroscopy, one can calculate the formation quantum yield of a certain compound's photoproduct characterized by difference molar absorption coefficient :
Note that in general means the difference in molar absorption coefficients contributing before and after the excitation so that . and are difference absorbance observed for compound of interest and the reference compound, respectively, for the relevant wavelengths. The formation quantum yield , as well as the difference molar absorption coefficient associated with the reference compound should be known before the experiment. The last term in the equation serves as a correction if the stationary absorbances of prepared solutions are not perfectly the same, however it shouldn't be far from unity. Excitation energy should be low enough to avoid nonlinear effect such as multiphoton absorption. This technique allows for characterization of certain photoproducts without explicit calculation of the number of absorbed photons, benefiting from the fact that imperfections of the measurement contribute in the same way for the compound of interest and the reference compound, so they effectively compensate.
Source: Wikipedia. Article content is retrieved live through the MediaWiki API.
An actinometer is an instrument that can measure the heating power of radiation. Actinometers are used in meteorology to measure solar radiation as pyranometers, pyrheliometers and net radiometers. An actinometer is a chemical system or physical device which determines the number of photons in a beam integrally or per unit time. This name is commonly applied to devices used in the ultraviolet and visible wavelength ranges. For example, solutions of iron(III) oxalate can be used as a chemical actinometer, while bolometers, thermopiles, and photodiodes are physical devices giving a reading that can be correlated to the number of photons detected.
A net radiometer is a type of actinometer used to measure net radiation (NR) at the Earth's surface for meteorological applications. The name net radiometer reflects the fact that it measures the difference between downward/incoming and upward/outgoing radiation from Earth. It is most commonly used in the field of ecophysiology.
A pyranometer (from Greek πῦρ (pyr) 'fire' and ἄνω (ano) 'above, sky') is a type of actinometer used for measuring solar irradiance on a planar surface and it is designed to measure the solar radiation flux density (W/m2) from the hemisphere above within a wavelength range 0.3 μm to 3 μm. A pyranometer with natural output does not require any power to operate as its transducers generates an electrical signal proportional to the solar irradiance. However, recent technical development includes use of electronics in pyranometers, which do require (low) external power.
In physics, optical depth or optical thickness is the natural logarithm of the ratio of incident to transmitted radiant power through a material. Thus, the larger the optical depth, the smaller the fraction of transmitted radiant power through the medium. Spectral optical depth or spectral optical thickness is the natural logarithm of the ratio of incident to transmitted spectral radiant power through a material. Optical depth is a dimensionless quantity. Although it is a monotonically increasing function of path length, it is not a physical distance itself, approaching zero as the path length vanishes. The use of the term "optical density" for optical depth is discouraged. In chemistry, a closely related quantity called absorbance (or decadic absorbance) is used instead of optical depth. Absorbance uses the common logarithm (base 10) of the ratio of incident to transmitted radiant power. It relates to optical depth by a factor of loge(10).
Before the 1921 destruction of Tulsa’s Greenwood District, Black residents had created a remarkable center of business and community life. The district included stores, professional offices, entertainment venues and homes owned by Black citizens. Understanding Greenwood means learning what was built—not only what was burned.