Civil Rights
Movements, leaders, victories and the continuing fight for equality.
Explore the people, places, events, achievements, struggles and stories that shaped our journey.
Movements, leaders, victories and the continuing fight for equality.
Innovation, patents, science, technology and world-changing contributions.
Pioneers, champions, Negro Leagues, records, activism and excellence.
Meet the people whose lives, choices and achievements shaped the journey.
Black towns, communities, institutions and places where history happened.
Moments that changed communities, movements, institutions and the nation.
Katherine Johnson’s mathematical calculations helped guide some of America’s most important early space missions while she confronted the racial and gender barriers faced by Black women in twentieth-century America.
MORE →Reflects the personal views, recollections, and perspective of the author, Mike Davis.
This is a personal recollection on the Move fire on May 13, 1985
| Computer network types by scale |
|---|
A body area network (BAN), also referred to as a wireless body area network (WBAN), a body sensor network (BSN) or a medical body area network (MBAN), is a wireless network of wearable computing devices.[1][2][3][4][5] BAN devices may be embedded inside the body as implants or pills,[6] may be surface-mounted on the body in a fixed position, or may be accompanied devices which humans can carry in different positions, such as in clothes pockets, by hand, or in various bags.[7]
Devices are becoming smaller, especially in body area networks. These networks include multiple small body sensor units (BSUs) and a single central unit (BCU).[8] Despite this trend, decimeter (tab and pad) sized smart devices still play an important role. They act as data hubs or gateways and provide a user interface for viewing and managing BAN applications on the spot.
The development of WBAN technology started around 1995 around the idea of using wireless personal area network (WPAN) technologies to implement communications on, near, and around the human body. About six years later, the term "BAN" came to refer to systems where communication is entirely within, on, and in the immediate proximity of a human body.[9][10] A WBAN system can use WPAN wireless technologies as gateways to reach longer ranges. Through gateway devices, it is possible to connect the wearable devices on the human body to the internet. This way, medical professionals can access patient data online using the internet independent of the patient location.[11]
The rapid growth in physiological sensors, low-power integrated circuits, and wireless communication has enabled a new generation of wireless sensor networks, now used for purposes such as monitoring traffic, crops, infrastructure, and health. The body area network field is an interdisciplinary area which could allow inexpensive and continuous health monitoring with real-time updates of medical records through the Internet. A number of intelligent physiological sensors can be integrated into a wearable wireless body area network, which can be used for computer-assisted rehabilitation or early detection of medical conditions. This area relies on the feasibility of implanting very small biosensors inside the human body that are comfortable and that don't impair normal activities. The implanted sensors in the human body will collect various physiological changes in order to monitor the patient's health status no matter their location. The information will be transmitted wirelessly to an external processing unit. This device will instantly transmit all information in real time to the doctors throughout the world. If an emergency is detected, the physicians will immediately inform the patient through the computer system by sending appropriate messages or alarms. Currently, the level of information provided and energy resources capable of powering the sensors are limiting. While the technology is still in its primitive stage it is being widely researched and once adopted, is expected to be a breakthrough invention in healthcare, leading to concepts like telemedicine and MHealth becoming real.
Initial applications of BANs are expected to appear primarily in the healthcare domain, especially for continuous monitoring and logging vital parameters of patients with chronic diseases such as diabetes, asthma and heart attacks.
Other applications of this technology include sports, military, or security. Extending the technology to new areas could also assist communication by seamless exchanges of information between individuals, or between individuals and machines.
The latest international standard for BANs is the IEEE 802.15.6 standard.[12]
A typical BAN or BSN requires vital sign monitoring sensors, motion detectors (through accelerometers) to help identify the location of the monitored individual and some form of communication, to transmit vital sign and motion readings to medical practitioners or care givers. A typical body area network kit will consist of sensors, a Processor, a transceiver and a battery. Physiological sensors, such as ECG and SpO2 sensors, have been developed. Other sensors such as a blood pressure sensor, EEG sensor and a PDA for BSN interface are under development.[13]
The FCC has approved the allocation of 40 MHz of spectrum bandwidth for medical BAN low-power, wide-area radio links at the 2360–2400 MHz band. This will allow off-loading MBAN communication from the already saturated standard Wi-Fi spectrum to a standard band.[14]
The 2360–2390 MHz frequency range is available on a secondary basis. The FCC will expand the existing Medical Device Radiocommunication (MedRadio) Service in Part 95 of its rules. MBAN devices using the band will operate under a 'license-by-rule' basis which eliminates the need to apply for individual transmitter licenses. Usage of the 2360–2390 MHz frequencies are restricted to indoor operation at health-care facilities and are subject to registration and site approval by coordinators to protect aeronautical telemetry primary usage. Operation in the 2390–2400 MHz band is not subject to registration or coordination and may be used in all areas including residential.[15]
Problems with the use of this technology could include:
{{cite journal}}: Cite uses deprecated parameter |citeseerx= (help)
{{cite web}}: CS1 maint: multiple names: authors list (link) CS1 maint: numeric names: authors list (link)
{{cite journal}}: Cite uses deprecated parameter |citeseerx= (help)
Source: Wikipedia. Article content is retrieved live through the MediaWiki API.
A body area network (BAN), also referred to as a wireless body area network (WBAN), a body sensor network (BSN) or a medical body area network (MBAN), is a wireless network of wearable computing devices. BAN devices may be embedded inside the body as implants or pills, may be surface-mounted on the body in a fixed position, or may be accompanied devices which humans can carry in different positions, such as in clothes pockets, by hand, or in various bags. Devices are becoming smaller, especially in body area networks. These networks include multiple small body sensor units (BSUs) and a single central unit (BCU). Despite this trend, decimeter (tab and pad) sized smart devices still play an important role. They act as data hubs or gateways and provide a user interface for viewing and managing BAN applications on the spot. The development of WBAN technology started around 1995 around the idea of using wireless personal area network (WPAN) technologies to implement communications on, near, and around the human body. About six years later, the term "BAN" came to refer to systems where communication is entirely within, on, and in the immediate proximity of a human body. A WBAN system can use WPAN wireless technologies as gateways to reach longer ranges. Through gateway devices, it is possible to connect the wearable devices on the human body to the internet. This way, medical professionals can access patient data online using the internet independent of the patient location.
Kaveh Pahlavan (Persian: کاوه پهلوان born in Tehran, Pahlavi Iran), was a Professor of Electrical and Computer Engineering and Computer Science and the director of the Center for Wireless Information Network Studies (CWINS), Worcester Polytechnic Institute, Worcester, Massachusetts. Pahlavan started doing research on Wi-Fi when it was in its infancy, and has worked on wireless indoor geolocation, and Body Area Networking. He contributed to numerous technical publications and holds a number of patents in these areas. His current area of research is opportunistic application of RF signals from wireless devices for gesture and motion detection as well as authentication and security.
The IEEE 802.15.6 standard is the latest international standard for Wireless Body Area Network (WBAN). WBAN supports a variety of real-time health monitoring and consumer electronics applications. The latest international standard for WBAN is the IEEE 802.15.6 standard which aims to provide an international standard for low power, short range, and extremely reliable wireless communication within the surrounding area of the human body, supporting a vast range of data rates for different applications. Short-range, wireless communications in the vicinity of, or inside, a human body (but not limited to humans) are specified in this standard. It uses existing industrial scientific medical (ISM) bands as well as frequency bands approved by national medical and/or regulatory authorities. Support for quality of service (QoS), extremely low power, and data rates up to 10 Mbps is required while simultaneously complying with strict non-interference guidelines where needed.
The Medical Device Radiocommunications Service (MedRadio) is a specification and communication spectrum created for and set aside by the U.S. Federal Communications Commission (FCC) for the communication needs of diagnostic and therapeutic medical implants and body-worn medical devices. Devices operating on MedRadio include cardiac pacemakers, defibrillators, neuromuscular stimulators, and drug delivery systems. As of February 2016, communications spectrum for these and other similar devices is set aside at various points in the 400 MHz frequency band, as well as the 2360-2400 MHz band, though specifically for medical body area network (MBAN) devices. The specification supersedes and incorporates a previous specification called the Medical Implant Communication Service (MICS). The specification and nearly identical spectrum have also been created by the European Telecommunications Standards Institute (ETSI), with the specification largely referred to as MICS/MEDS (Medical Data Service) in Europe and other parts of the world.
Before the 1921 destruction of Tulsa’s Greenwood District, Black residents had created a remarkable center of business and community life. The district included stores, professional offices, entertainment venues and homes owned by Black citizens. Understanding Greenwood means learning what was built—not only what was burned.
MORE →Shirley Chisholm, elected in 1968.